CONFIGURE THE PART NUMBER
IF YOU KNOW COMPLETE P/N, ENTER HERE: NTM-                        
Please select an option for each digit, then click the "SUBMIT" button at the bottom.
NOTE: Options which are incompatible will be grayed out and cannot be selected.
To access these options please select "RESET ALL."
Selected Part Number: NTM-3-_ _ -
DIGIT OPTIONS
SERIAL I/O (Digit 5): 0: USB
1: RS485
2: Ethernet
3: USB & µSD Memory
4: RS485 & µSD Memory
9: Custom - Contact OTEK
GRADE (Digit 6): 0: Industrial & Plastic
I: Industrial & Metal
3: Industrial & Metal NEMA 4X
M: To Mil-Spec & Metal (Contact OTEK)
E: To EPRI-Nuclear & Metal (Contact OTEK)
9: Custom - Contact OTEK
# OF CHANNELS (Digit 7): 1: ONE
2: TWO
3: THREE
9: Custom - Contact OTEK
INPUT SIGNAL (Digits 8&9): 00: 4-20mA, All Channels=Input, Loop Power
01: Volts A.C., All Channels, Signal Power
02: 5 Amps A.C., All Channels, Signal Power
03: Watts A.C., All Channels, Signal Power
04: Hertz A.C.V., All Channels, Signal Power
05: Mixed 2 Channel: VAC Ch. 1, AAC Ch. 2 ,Signal Power
06: Mixed 2 Channel: VAC Ch. 1, WAC Ch. 2, Signal Power
07: Mixed 2 Channel: VAC Ch. 1, Hz Ch. 2, Signal Power
08: Mixed 2 Channel: AAC Ch.1, WAC Ch. 2, Signal Power
09: Custom - Contact OTEK
10: Mixed 3 Channel: V Ch. 1, A Ch. 2, W, Ch. 3, Signal Power
11: Mixed 3 Channel: V Ch. 1, A Ch. 2, Hz Ch. 3, Signal Power
12: Mixed 3 Channel: V Ch. 1, W Ch. 2, Hz Ch. 3, Signal Power
13: Mixed 3 Channel: A Ch. 1, W Ch. 2, Hz, Ch. 3 Signal Power
16: 7-140 Volts A.C./D.C., All Channels, Signal Power
17: 10-50mA, All Channels=Input, Loop Power
18: 10-500mADC, All Channels=Input, Signal Power
20: 4-20mA F.S. (All Channels Same Input)
21: 100mV DC F.S.
22: 1VDC F.S
23: 10VDC F.S.
24: 100VDC F. S.
25: 10mADC F. S.
26: 100mADC F.S.
27: Watts DC (1Vx1A) F.S.
28: Watts DC (1Vx1V) F.S.
29: Custom - Contact OTEK
30: 0.1V RMS F. S.
31: 1V RMS F.S
32: 10V RMS F.S.
33: 150V RMS F.S.
34: 250 V RMS F.S.
35: 0.1A RMS F.S.
36: 1A RMS F.S.
37: 5A RMS F.S
38: W RMS (1Vx1VAC) F.S.
40: W RMS (120Vx5A AC) F. S.
41: Hertz (10KHz/5V Logic) F.S.
43: Hertz (240VAC/30-100 Hz) F.S.
44: Hertz (120VAC/500 Hz) F.S.
45: Strain-Gage (?300<4K Ohm)
47: RTD (PT100)
48: RTD (PT1000)
50: TC (Type J)
51: TC (Type K)
52: TC (Type T)
53: pH (0-14.00)
54: ORP (0-2000mVDC)
55: % RH (Specify Sensor)
56: Resistance (0-10K Ohm)
57: 10-50mA F.S.
58: None (Serial Input Remote Meter-1 Channel)
60: 1V Ch.1, 1A Ch.2 (.2 Ohm) DC
61: 10V Ch.1, 1A, Ch.2 (.2 Ohm) DC
62: 100V Ch.1, 1A Ch.2 (.2 Ohm) DC
63: 100V Ch.1, 5A Ch.2 (0.02 Ohm) DC
64: 150V Ch.1, 5A Ch.2 (.04 Ohm) RMS
65: 250V Ch.1, 5A Ch.2 (.04 Ohm) RMS
66: 150V Ch.1, 100Hz Ch.2 (120 V Line) RMS
67: 250V Ch.1, 100 Hz Ch.2 (240V Line) RMS
68: None (Serial Input Remote Meter-2 Channel)
69: Custom - Contact OTEK
70: 1V Ch.1, 1A Ch.2 (.2 Ohm), W Ch.3 DC
71: 10V Ch.1, 1A Ch.2 (.2 Ohm), W Ch.3 DC
72: 100V Ch.1, 1A Ch.2 (.2 Ohm), W Ch.3 DC
73: 100V Ch.1, 5A Ch.2 (0.02 Ohm), W Ch.3 DC
74: 150V Ch.1, 5A Ch.2 (.04 Ohm), W Ch.3 RMS
75: 250V Ch.1, 5A Ch.2 (.04Ohm), W Ch.3 RMS
76: 150V Ch.1, 5A Ch. 2 (.04Ohm), 100Hz Ch.3 RMS
77: 250V Ch.1, 5A Ch. 2 (.04Ohm), 100Hz Ch.3 RMS
78: None (Serial Input Remote Meter-3 Channel)
79: Custom - Contact OTEK
42: Hertz (120VAC/40-100 Hz) F.S
POWER INPUT (Digit 10): 1: Non-Isolated USB
2: Isolated 5VDC
3: Isolated 7-32VDC
4: Isolated 90-265VAC
9: Custom - Contact OTEK
0: Powerless™ (No Power)
CONTROL OUTPUTS (Digit 11): 1: CH. 1: O.C.T. (4)
2: CH. 1: Relays (4)
3: CH. 1 & 2: O.C.T. (8)
4: CH. 1 & 2: Relays (8)
5: CH. 1, 2 & 3: .O.C.T. (12)
6: CH. 1, 2 & 3: Relays (12)
0: None
9: Custom - Contact OTEK
C: H.V. SPDT Reed Relay (4)
D: H.V. SPDT Reed Relay (8)
E: H.V. SPDT Reed Relay (12)
F: H.V. SPDT Reed Relay (16)
G: H.V. SPDT MOSFET (4)
H: H.V. SPDT MOSFET (8)
J: H.V. SPDT MOSFET (12)
K: H.V. SPDT MOSFET (16)
ANALOG/POWER OUTPUT (Digit 12): 1: CH. 1: 4-20mA Out
2: CH. 1: 30V Out
3: CH. 1 & 2: 4-20mA Out
4: CH. 1 & 2: 30V Out
5: CH. 1, 2 & 3: 4-20mA Out
6: CH. 1, 2 & 3: 30V Out
9: Custom (Contact OTEK)
0: None
SCALE PLATE (Digit 13): 0: Standard (0-100%)
9: Custom - Contact OTEK
RANGE/CALIBRATION (Digit 14): 0: Standard (0-100%)
9: Custom - Contact OTEK
OPTIONAL NOTES:

Model NTM-3

Note:
1) If you select USB as the Power Input (Digit 10, Option 1), you must select USB as the Serial I/O (Digit 5, Option 0).
2) The number of Outputs (Digits 11 and 12) cannot exceed the number of Channels (Digit 7).