CONFIGURE THE PART NUMBER
Please select an option for each digit, then click the "SUBMIT" button at the bottom.
NOTE: Options which are incompatible will be grayed out and cannot be selected.
To access these options please select "RESET ALL."
NOTE: Options which are incompatible will be grayed out and cannot be selected.
To access these options please select "RESET ALL."
Selected Part Number: NTM-B_ _ _ -_ _ _ -_ _ _ _ |
DIGIT | OPTIONS |
SERIAL I/O (Digit 5): |
0: USB
1: RS485 2: Ethernet 3: USB & µSD Memory 4: RS485 & µSD Memory 9: Custom - Contact OTEK |
GRADE (Digit 6): |
0: Industrial & Plastic
I: Industrial & Metal 2: Industrial & Plastic NEMA 4X 3: Industrial & Metal NEMA 4X M: To Mil-Spec & Metal (Contact OTEK) E: To EPRI-Nuclear & Metal (Contact OTEK) 9: Custom - Contact OTEK |
# OF CHANNELS (Digit 7): |
1: ONE
9: Custom - Contact OTEK |
INPUT SIGNAL (Digits 8&9): |
00: 4-20mA, All Channels=Input, Loop Power
01: Volts A.C., All Channels, Signal Power 02: 5 Amps A.C., All Channels, Signal Power 03: Watts A.C., All Channels, Signal Power 04: Hertz A.C.V., All Channels, Signal Power 09: Custom - Contact OTEK 16: 7-140 Volts A.C./D.C., All Channels, Signal Power 17: 10-50mA, All Channels=Input, Loop Power 18: 10-500mADC, All Channels=Input, Signal Power 20: 4-20mA F.S. (All Channels Same Input) 21: 100mV DC F.S. 22: 1VDC F.S 23: 10VDC F.S. 24: 100VDC F. S. 25: 10mADC F. S. 26: 100mADC F.S. 27: Watts DC (1Vx1A) F.S. 28: Watts DC (1Vx1V) F.S. 29: Custom - Contact OTEK 30: 0.1V RMS F. S. 31: 1V RMS F.S 32: 10V RMS F.S. 33: 150V RMS F.S. 34: 250 V RMS F.S. 35: 0.1A RMS F.S. 36: 1A RMS F.S. 37: 5A RMS F.S 38: W RMS (1Vx1VAC) F.S. 40: W RMS (120Vx5A AC) F. S. 41: Hertz (10KHz/5V Logic) F.S. 43: Hertz (240VAC/30-100 Hz) F.S. 44: Hertz (120VAC/500 Hz) F.S. 45: Strain-Gage (?300<4K Ohm) 47: RTD (PT100) 48: RTD (PT1000) 50: TC (Type J) 51: TC (Type K) 52: TC (Type T) 53: pH (0-14.00) 54: ORP (0-2000mVDC) 55: % RH (Specify Sensor) 56: Resistance (0-10K Ohm) 57: 10-50mA F.S. 58: None (Serial Input Remote Meter-1 Channel) 42: Hertz (120VAC/40-100 Hz) F.S |
POWER INPUT (Digit 10): |
1: Non-Isolated USB
2: Isolated 5VDC 3: Isolated 7-32VDC 4: Isolated 90-265VAC 9: Custom - Contact OTEK 0: Powerless™ (No Power) |
CONTROL OUTPUTS (Digit 11): |
1: CH. 1: O.C.T. (4)
2: CH. 1: Relays (4) 0: None 9: Custom - Contact OTEK C: H.V. SPDT Reed Relay (4) D: H.V. SPDT Reed Relay (8) E: H.V. SPDT Reed Relay (12) F: H.V. SPDT Reed Relay (16) G: H.V. SPDT MOSFET (4) H: H.V. SPDT MOSFET (8) J: H.V. SPDT MOSFET (12) K: H.V. SPDT MOSFET (16) |
ANALOG/POWER OUTPUT (Digit 12): |
1: CH. 1: 4-20mA Out
2: CH. 1: 30V Out 9: Custom (Contact OTEK) 0: None |
SCALE PLATE (Digit 13): |
0: Standard (0-100%)
9: Custom - Contact OTEK |
RANGE/CALIBRATION (Digit 14): |
0: Standard (0-100%)
9: Custom - Contact OTEK |
OPTIONAL NOTES: |
Model NTM-B
Note:
1) If you select USB as the Power Input (Digit 10, Option 1), you must select USB as the Serial I/O (Digit 5, Option 0).
2) The number of Outputs (Digits 11 and 12) cannot exceed the number of Channels (Digit 7).
1) If you select USB as the Power Input (Digit 10, Option 1), you must select USB as the Serial I/O (Digit 5, Option 0).
2) The number of Outputs (Digits 11 and 12) cannot exceed the number of Channels (Digit 7).