CONFIGURE THE PART NUMBER
IF YOU KNOW COMPLETE P/N, ENTER HERE: NTM-                        
Please select an option for each digit, then click the "SUBMIT" button at the bottom.
NOTE: Options which are incompatible will be grayed out and cannot be selected.
To access these options please select "RESET ALL."
Selected Part Number: NTM-P-_ _ -
DIGIT OPTIONS
SERIAL I/O (Digit 5): 0: USB
1: RS485
9: Custom - Contact OTEK
GRADE (Digit 6): 0: Industrial & Plastic
H: Horizontal Industrial & Plastic (-P only)
2: Industrial & Plastic NEMA 4X
4: Horizontal I & P NEMA 4X (-P only)
9: Custom - Contact OTEK
# OF CHANNELS (Digit 7): 1: ONE
9: Custom - Contact OTEK
INPUT SIGNAL (Digits 8&9): 00: 4-20mA, All Channels=Input, Loop Power
01: Volts A.C., All Channels, Signal Power
02: 5 Amps A.C., All Channels, Signal Power
03: Watts A.C., All Channels, Signal Power
04: Hertz A.C.V., All Channels, Signal Power
09: Custom - Contact OTEK
16: 7-140 Volts A.C./D.C., All Channels, Signal Power
17: 10-50mA, All Channels=Input, Loop Power
18: 10-500mADC, All Channels=Input, Signal Power
20: 4-20mA F.S. (All Channels Same Input)
21: 100mV DC F.S.
22: 1VDC F.S
23: 10VDC F.S.
24: 100VDC F. S.
25: 10mADC F. S.
26: 100mADC F.S.
27: Watts DC (1Vx1A) F.S.
28: Watts DC (1Vx1V) F.S.
29: Custom - Contact OTEK
30: 0.1V RMS F. S.
31: 1V RMS F.S
32: 10V RMS F.S.
33: 150V RMS F.S.
34: 250 V RMS F.S.
35: 0.1A RMS F.S.
36: 1A RMS F.S.
37: 5A RMS F.S
38: W RMS (1Vx1VAC) F.S.
40: W RMS (120Vx5A AC) F. S.
41: Hertz (10KHz/5V Logic) F.S.
43: Hertz (240VAC/30-100 Hz) F.S.
44: Hertz (120VAC/500 Hz) F.S.
45: Strain-Gage (?300<4K Ohm)
47: RTD (PT100)
48: RTD (PT1000)
50: TC (Type J)
51: TC (Type K)
52: TC (Type T)
53: pH (0-14.00)
54: ORP (0-2000mVDC)
55: % RH (Specify Sensor)
56: Resistance (0-10K Ohm)
57: 10-50mA F.S.
58: None (Serial Input Remote Meter-1 Channel)
42: Hertz (120VAC/40-100 Hz) F.S
POWER INPUT (Digit 10): 1: Non-Isolated USB
2: Isolated 5VDC
3: Isolated 7-32VDC
4: Isolated 90-265VAC
9: Custom - Contact OTEK
0: Powerless™ (No Power)
CONTROL OUTPUTS (Digit 11): 1: CH. 1: O.C.T. (4)
2: CH. 1: Relays (4)
A: CH. 1: (-H,-P,-S & -X Only) O.C.T. (2)
B: CH. 1: (-H,-P,-S & -X Only) Relays (2)
0: None
9: Custom - Contact OTEK
C: H.V. SPDT Reed Relay (4)
D: H.V. SPDT Reed Relay (8)
E: H.V. SPDT Reed Relay (12)
F: H.V. SPDT Reed Relay (16)
G: H.V. SPDT MOSFET (4)
H: H.V. SPDT MOSFET (8)
J: H.V. SPDT MOSFET (12)
K: H.V. SPDT MOSFET (16)
ANALOG/POWER OUTPUT (Digit 12): 1: CH. 1: 4-20mA Out
2: CH. 1: 30V Out
9: Custom (Contact OTEK)
0: None
SCALE PLATE (Digit 13): 0: Standard (0-100%)
9: Custom - Contact OTEK
RANGE/CALIBRATION (Digit 14): 0: Standard (0-100%)
9: Custom - Contact OTEK
OPTIONAL NOTES:

Model NTM-P

Note:
1) If you select USB as the Power Input (Digit 10, Option 1), you must select USB as the Serial I/O (Digit 5, Option 0).
2) The number of Outputs (Digits 11 and 12) cannot exceed the number of Channels (Digit 7).