CONFIGURE THE PART NUMBER
IF YOU KNOW COMPLETE P/N, ENTER HERE: UPM-                          
Please select an option for each digit, then click the "Submit" button at the bottom.
NOTE: As you select your options, later options which are incompatible will be grayed out and cannot be selected.
To access these options please select "Reset All."
Selected Part Number: UPM-H-_ _ -
DIGIT OPTIONS
SERIAL I/O (Digit 5): 0: USB
1: RS485
9: Custom - Contact OTEK
GRADE (Digit 6): 0: Industrial & Plastic
2: Industrial & Plastic NEMA 4X
9: Custom - Contact OTEK
# OF CHANNELS (Digit 7): 1: ONE
2: TWO
9: Custom - Contact OTEK
INPUT SIGNAL (Digits 8&9): 01: Volts A.C., All Channels, Signal Power
02: 5 Amps A.C., All Channels, Signal Power
03: Watts A.C., All Channels, Signal Power
04: Hertz A.C.V., All Channels, Signal Power
05: Mixed 2 Channel: VAC Ch. 1, AAC Ch. 2 ,Signal Power
06: Mixed 2 Channel: VAC Ch. 1, WAC Ch. 2, Signal Power
07: Mixed 2 Channel: VAC Ch. 1, Hz Ch. 2, Signal Power
08: Mixed 2 Channel: AAC Ch.1, WAC Ch. 2, Signal Power
09: Custom - Contact OTEK
16: 7-140 Volts A.C./D.C., All Channels, Signal Power
17: 10-50mA, All Channels=Input, Loop Power
18: 10-500mADC, All Channels=Input, Signal Power
20: 4-20mA F.S. (All Channels Same Input)
21: 100mV DC F.S.
22: 1VDC F.S
23: 10VDC F.S.
24: 100VDC F. S.
25: 10mADC F. S.
26: 100mADC F.S.
27: Watts DC (1Vx1A) F.S.
28: Watts DC (1Vx1V) F.S.
29: Custom - Contact OTEK
30: 0.1V RMS F. S.
31: 1V RMS F.S
32: 10V RMS F.S.
33: 150V RMS F.S.
34: 250 V RMS F.S.
35: 0.1A RMS F.S.
36: 1A RMS F.S.
37: 5A RMS F.S
38: W RMS (1Vx1VAC) F.S.
40: W RMS (120Vx5A AC) F. S.
41: Hertz (10KHz/5V Logic) F.S.
42: Hertz (120VAC/40-100 Hz) F.S
43: Hertz (240VAC/30-100 Hz) F.S.
44: Hertz (120VAC/500 Hz) F.S.
45: Strain-Gage (?300<4K Ohm)
47: RTD (PT100)
48: RTD (PT1000)
50: TC (Type J)
51: TC (Type K)
52: TC (Type T)
53: pH (0-14.00)
54: ORP (0-2000mVDC)
55: % RH (Specify Sensor)
56: Resistance (0-10K Ohm)
57: 10-50mA F.S.
58: None (Serial Input Remote Meter-1 Channel)
1A: Any Digit 15, TTL Input Level
1B: Any Digit 15, H.V. Input Level
1C: Any Digit 15, V-F (Option K) Input Level
60: 1V Ch.1, 1A Ch.2 (.2 Ohm) DC
61: 10V Ch.1, 1A, Ch.2 (.2 Ohm) DC
62: 100V Ch.1, 1A Ch.2 (.2 Ohm) DC
63: 100V Ch.1, 5A Ch.2 (0.02 Ohm) DC
64: 150V Ch.1, 5A Ch.2 (.04 Ohm) RMS
65: 250V Ch.1, 5A Ch.2 (.04 Ohm) RMS
66: 150V Ch.1, 100Hz Ch.2 (120 V Line) RMS
67: 250V Ch.1, 100 Hz Ch.2 (240V Line) RMS
68: None (Serial Input Remote Meter-2 Channel)
69: Custom - Contact OTEK
2A: Any Digit 15 TTL Input Level
2B: Any Digit 15 H.V. Input Level
2C: Any Digit 15 V-F (Option K) Input Level
79: Custom - Contact OTEK
89: Custom - Contact OTEK
00: 4-20mA, All Channels=Input, Loop Power
POWER INPUT (Digit 10): 0: Powerless™ (No Power)
1: Non-Isolated USB
2: Isolated 5VDC
3: Isolated 7-32VDC
4: Isolated 90-265VAC
9: Custom - Contact OTEK
CONTROL OUTPUTS (Digit 11): 1: CH. 1: O.C.T. (4)
2: CH. 1: Relays (4)
3: CH. 1 & 2: O.C.T. (8)
4: CH. 1 & 2: Relays (8)
9: Custom - Contact OTEK
0: None
C: H.V. SPDT REED RELAY (4)
D: H.V. SPDT REED RELAY (8)
E: H.V. SPDT REED RELAY (12)
F: H.V. SPDT REED RELAY (16)
G: H.V. SPDT MOSFET (4)
H: H.V. SPDT MOSFET (8)
J: H.V. SPDT MOSFET (12)
K: H.V. SPDT MOSFET (16)
ANALOG/POWER OUTPUT (Digit 12): 0: None
1: CH. 1: 4-20mA Out
2: CH. 1: 30V Out
3: CH. 1 & 2: 4-20mA Out
4: CH. 1 & 2: 30V Out
9: Custom - Contact OTEK
SCALE PLATE (Digit 13): 0: Standard
9: Custom - Contact OTEK
RANGE/CALIBRATION (Digit 14): 0: Standard
9: Custom - Contact OTEK
COUNTER/FUNCTIONS (Digit 15): 0: None (Use Digits 8 & 9)
1: Up/ Down Counter
2: Totalizer
3: Quadrature
4: Batch
5: Frequency
6: Period
7: RADS
8: REM
9: Custom
A: Up/ Down Timer
B: Time Interval
C: Elapsed Time
D: Range
E: Julian Clock
F: Rate
G: Ratio
H: Phase Angle
L: Integration
K: V-F (Voltage to Frequency)
M: Pulse Width
OPTIONAL NOTES:

Model UPM-H

Note:

1) If you select USB as the Power Input (Digit 10, Option 1), you must select USB as the Serial I/O (Digit 5, Option 0).

2) The number of Outputs (Digits 11 and 12) cannot exceed the number of Channels (Digit 7).

3) If you select Option 0 (None) on Digit 15, you cannot have options 1A-1C as your Input Signal on Digits 8 & 9.